55337
| 1 | 1. | 1000 Edgewood College Drive | Miscellaneous | 1000 Edgewood College Dr.
BLDNCC-2013-06890
Michael Guns of Edgewood College is seeking a variance to request a special locking system for after hours for safety issues, such as an active shooter, appealing IBC 1010.1.9, which requires all exit doors to open from the egree side at all times. The City of Madison Fire Department has conditionally approved the variance.
Alder District #13 | Table | |
Action details
|
Not available
|
55884
| 1 | 2. | 308 N. Carroll St. | Miscellaneous | 308 N. Carroll St.
BLDVAR-2019-07150
Scott Pratt of Live Here, LLC is seeking a variance from IBC 1011.10 to allow a spiral stair to be used as an exit for space of 900 sp. ft. and 8 occupants. The proposed stair was previously considered with no action taken by the Building Board of Appeals. Design alterations have been made to the stairway to meet the code requirements except for the required 7.5" tread depth at a point 12" from the narrow edge.
Alder District #4 | Approve | |
Action details
|
Not available
|
55898
| 1 | 3. | 1513 Parkside Dr. | Miscellaneous | 1513 Parkside Dr.
Brendan Kress of Strand Associates, Inc. is seeking a variance to exit through an adjacent tenant space. IBC 1016.2.1 prohibits exiting through adjacent tenant space. The City of Madison Fire Department supports this variance with the condition the future renovations shall attempt to streamline the exiting; the exit signs and emergency lighting shall comply with the 2015 IBC.
Alder District #17 | Approve | |
Action details
|
Not available
|
55929
| 1 | 4. | 1783 Thierer Rd. | Miscellaneous | 1783 Thierer Rd.
Joel Bahr of Executive Investors is seeking a variance to allow a limited sprinkler system installation for an alteration of an existing vacant tenant office to assembly use. IBC 903.2.1.2 requires an automatic sprinkler system for A-2 Occupancies exceeding 5,000 sq. ft. and A-3 Occupancies exceeding 12,000 sq. ft. The City of Madison Fire Department supports this variance with the condition that a new water line sufficient to serve a sprinkler system for the entire building be provided. That an automatic sprinkler system be installed in the proposed areas being renovated. That future additional sprinkler systems be installed within un-sprinklered spaces prior to occupancy by a new tenant or for any future level II alterations throughout the building.
Alder District #17 | Approve | |
Action details
|
Not available
|