55884
| 1 | 1. | 308 N. Carroll St. | Miscellaneous | 308 N. Carroll St.
BLDVAR-2019-07150
Scott Pratt of Live Here, LLC is seeking a variance from IBC 1011.10 to allow a spiral stair to be used as an exit for space of 900 sp. ft. and 8 occupants. The proposed stair was previously considered with no action taken by the Building Board of Appeals. Design alterations have been made to the stairway to meet the code requirements except for the required 7.5" tread depth at a point 12" from the narrow edge.
Alder District #4 | Withdrawn by Applicant | |
Action details
|
Not available
|
56348
| 1 | 2. | 1277 Demimg Way | Miscellaneous | 1277 Deming Way
BLDVAR-2019-07800
Dean Health Plan Inc. is seeking a variance to allow for an exemption of SPS 363.0401 and SPS 363.0402, requiring structures that are heated and cooled to meet the IECC standards.
Alder District #9 | Table | |
Action details
|
Not available
|
56350
| 1 | 3. | 5006 Buckeye Rd. | Miscellaneous | 5006 Buckeye Rd.
BLDVAR-2019-07776
Mike Foerster Real Estate is seeking a variance from SPS 321.06, requiring a minimum headroom of 7 ft. fir 50% of habitable room. A previous second-level attic storage space has been opened, finished, and converted to habitable space that is open to the lower level with an approximate headroom of 54" (4'6") at the center and 24" (2') at the edges.
Proposed equivalence:
1. Install guard rail 36" in height over open area to lower level.
2. Interconnected smoke detector in area.
3. Tempered glass or safety film on window in area.
4. Designate area not to be used for sleeping.
Alder District #15 | Withdrawn by Applicant | |
Action details
|
Not available
|
56351
| 1 | 4. | 1953 Schlimgen Ave. | Miscellaneous | 1953 Schlimgen Ave.
BLDVAR-2019-07803
Michael Moline is seeking a variance from:
1. SPS 321.04 (2)d1 - Stairways shall be provided with a minimum headroom clearance of 76 in. measured vertically from a line parallel to the nosing of the treads to the ceiling, soffit, or any overhead obstruction directly above that line. Headroom at the bottom of the basement stairs is 75"; needs 76"
2. SPS 321.04 (2)d1 - Stairways shall be provided with a minimum headroom clearance of 76 in. measured vertically from a line parallel to the nosing of the treads to the ceiling, soffit, or any overhead obstruction directly above that line. Headroom at the top of the basement stairs is 60"; needs 76"
3. SPS 321.06 - All habitable rooms, kitchens, hallways, bathrooms, and corridors shall have a ceiling height of at least 7 ft. Attic room ceiling height is 5'9" at peak and 3' at knee walls; need 7' height for 50% of room.
4. SPS 321.04(2)a1 - Stairways shall measure at least 36 in. in width. Stair width to the attic is 21" at last five steps; need 36".
5. SPS 321.05 - The area of the glazed openings shall | Approve with Amendment(s) | |
Action details
|