Madison, WI Header
File #: 27640    Version: 1 Name: 306 W. Main Street - Party Walls
Type: Miscellaneous Status: Approved
File created: 9/11/2012 In control: BUILDING CODE, FIRE CODE, CONVEYANCE CODE AND LICENSING APPEALS BOARD
On agenda: Final action: 10/16/2012
Enactment date: Enactment #:
Title: 306 W. Main Street (C-09-45-2012) Iconica appealing IBC 706.1, Party Walls. The rule requires a fire wall be constructed along the internal property line without openings. The Variance requested is to build a "L" shaped building across an internal property line. The equivalency offered is there is an eighteen inch concrete deck over the parking garage below and a fire wall will be constructed at the property line. The openings will be protected with fire doors/shutters. This projection is on one piece of land, built in four stages. The final stage is completely separated from the rest of the complex.
Attachments: 1. 306 W Main Street_Party Walls.pdf, 2. Main St 306 W IBC 706 Rvsd App MFD statement 10-11-12.pdf
Title
306 W. Main Street (C-09-45-2012)
Iconica appealing IBC 706.1, Party Walls. The rule requires a fire wall be constructed along the internal property line without openings.  The Variance requested is to build a "L" shaped building across an internal property line.  The equivalency offered is there is an eighteen inch concrete deck over the parking garage below and a fire wall will be constructed at the property line.  The openings will be protected with fire doors/shutters.  This projection is on one piece of land, built in four stages.  The final stage is completely separated from the rest of the complex.